| Bare Overhead Conductors | ![]() |
Aluminum Conductor Steel Reinforced (ACSR)
All Aluminum Conductor (AAC)
Applications
The bare aluminum and ACSR conductors described here are suitable for installation in all practical spans on transmission towers, wood poles and other structures, ranging from long distance EHV transmission lines to sub-service spans at distribution or utilization voltages on private premises.
The choice of conductor size, type and strength should take into account factors such as electrical load, voltage regulation, corona losses, ice and wind loading, extreme temperatures and vibration. Nexans is prepared to assist in the evaluation of these factors as they apply to specific installations.
Aluminum Conductor Steel Reinforced (ACSR) Conductors Design Data
| Conductor | Standard Packages | ||||
| Code Word | Size (AWG or cmil) |
No. of
Wires (Al/Steel) |
Weight (lb/1000 ft) |
Conductor
Weight per
Package (lb) |
Conductor
Length per
Package (ft) |
| Turkey | 6 |
6/1 |
36.1 |
590 |
16340 5400 |
Swan |
4 |
6/1 |
57.4 |
885 220 |
15420 3835 |
Swanate |
4 |
7/1 |
67.0 |
1200 600 240 |
17910 8955 3580 |
Sparrow |
2 |
6/1 |
91.3 |
1770 885 220 |
19390 9695 2410 |
Sparate |
2 |
7/1 |
106.7 |
1200 600 240 |
11250 5625 2250 |
Raven |
1/0 |
6/1 |
145.2 |
1770 885 220 |
12190 6095 1515 |
Quail |
2/0 |
6/1 |
183.1 |
1770 885 |
9670 4835 |
Pigeon |
3/0 |
6/1 |
230.8 |
1770 885 |
7670 3835 |
Penguin |
4/0 |
6/1 |
291.1 |
1770 885 |
6080 3040 |
Waxwing |
266 800 |
18/1 |
290 |
4160 2080 |
14360 7180 |
Partridge |
266 800 |
26/7 |
367 |
3795 | 10330 |
Merlin |
336 400 |
18/1 |
365 |
4160 2080 |
11390 5695 |
Linnet |
336 400 |
26/7 |
463 |
3795 | 8195 |
Oriole |
336 400 |
30/7 |
527 |
4970 | 9430 |
Chickadee |
397 500 |
18/1 |
432 |
4160 2080 |
9630 4815 |
Ibis |
397 500 |
26/7 |
547 |
3795 | 6935 |
Pelican |
477 000 |
18/1 |
518 |
4160 2080 |
8030 4015 |
Flicker |
477 000 |
24/7 |
615 |
3275 | 5330 |
Hawk |
477 000 |
26/7 |
657 |
3795 | 5780 |
Hen |
477 000 |
30/7 |
747 |
4970 | 6650 |
Osprey |
556 500 |
18/1 |
604 |
2080 | 3445 |
Parakeet |
556 500 |
24/7 |
717 |
3275 | 4570 |
Dove |
556 500 |
26/7 |
766 |
3795 | 4955 |
Rook |
636 000 |
24/7 |
819 |
3275 | 4000 |
Grosbeak |
636 000 |
26/7 |
875 |
3795 | 4335 |
Cuckoo |
795 000 |
24/7 |
1023 |
3275 | 3200 |
Drake |
795 000 |
26/7 |
1094 |
3795 | 3470 |
| Tern | 795 000 | 45/7 | 896 | 3585 | 4000 |
Rail |
945 000 |
45/7 |
1075 |
3585 | 3335 |
Bluejay |
1 113 000 |
45/7 |
1255 |
3585 | 2855 |
| Bunting | 1 192 500 | 45/7 | 1344 | 3585 | 2665 |
Bittern |
1 272 000 |
45/7 |
1434 |
3585 | 2500 |
Lapwing |
1 590 000 |
45/7 |
1792 |
3585 | 2000 |
1350 All Aluminum Conductor (AAC) Design Data
|
Conductor |
Standard Packages |
||||
| Code Word |
Size |
No. of
Wires |
Weight |
Conductor Weight per Package (lb) | Conductor
Length per Package (ft) |
Peachbell |
6 |
7 |
24.6 |
1400 700 200 |
56910 28455 8130 |
Rose |
4 |
7 |
39.2 |
1400 700 200 |
35710 17855 5100 |
Iris |
2 |
7 |
62.3 |
1400 700 200 |
22470 11235 3210 |
Pansy |
1 |
7 |
78.5 |
1400 700 200 |
17830 8915 2550 |
Poppy |
1/0 |
7 |
99.1 |
1400 700 200 |
14130 7065 2020 |
Aster |
2/0 |
7 |
124.9 |
1400 700 |
11210 5605 |
Phlox |
3/0 |
7 |
157.5 |
1400 700 |
8890 4445 |
Oxlip |
4/0 |
7 |
198.6 |
1400 700 |
7050 3525 |
Daisy |
266 800 |
7 |
250.5 |
1400 700 |
5590 2795 |
Laurel |
266 800 |
19 |
250.5 |
3800 1900 |
15170 7585 |
Tulip |
336 400 |
19 |
315.8 |
3800 1900 |
12030 6015 |
Cosmos |
477 000 |
19 |
447.8 |
3800 1900 |
8490 4245 |
Dahlia |
556 500 |
19 |
522.4 |
3800 1900 |
7270 3635 |
Orchid |
636 000 |
37 |
597.0 |
3700 1850 |
6200 3100 |
Violet |
715 000 |
37 |
671.7 |
3700 1850 |
5510 2755 |
Arbutus |
795 000 |
37 |
746.3 |
3700 1850 |
4960 2480 |
Magnolia |
954 000 |
37 |
895.6 |
3700 1850 |
4130 2065 |
Bluebell |
1 033 500 |
37 |
970.2 |
3700 1850 |
3815 1910 |