1C TECK 90 (XLPE) Minus 40°C 1000 V

With Concentric Bonding Conductor
*Aluminum Armour Only

Conductor Size

Insulation
Thickness

Inner
Jacket
Thickness

Approximate Diameters Approx
Weight
Aluminum
Armour*
Copper
Content
kg/km
Inner
Jacket
Armour Outer
Covering
Power AWG
or kcmil
Bonding
AWG
inches mm inches mm inches mm inches mm inches mm lb/kft kg/km
6 8 0.060 1.52 0.030 0.76 0.453 11.50 0.693 17.60 0.791 20.09 331 493 210
4 6 0.060 1.52 0.030 0.76 0.497 12.63 0.737 18.72 0.835 21.21 428 637 330
 
3 6 0.060 1.52 0.030 0.76 0.525 13.33 0.765 189.43 0.863 21.92 473 704 382
2 6 0.060 1.52 0.030 0.76 0.555 14.10 0.795 20.19 0.893 22.68 528 786 446
1 4 0.080 2.03 0.045 1.14 0.658 16.70 0.898 22.81 0.996 25.30 696 1036 599
 
1/0 4 0.080 2.03 0.045 1.14 0.725 18.42 0.965 24.51 1.069 27.15 781 1162 701
2/0 4 0.080 2.03 0.045 1.14 0.750 19 05 1.025 26.04 1.135 28.83 944 1405 830
3/0 3 0.080 2.03 0.045 1.14 0.807 20.49 1.070 27.18 1.180 29.97 1121 1668 1051
4/0 3 0.080 2.03 0.045 1.14 0.859 21.82 1.134 28.80 1.244 31.60 1272 1893 1257
 
250 2 0.090 2.29 0.060 1.52 0.955 24.25 1.247 31.67 1.355 34.42 1466 2181 1500
300 2 0.090 2.29 0.060 1.52 1.005 25.53 1.280 32.51 1.409 35.79 1715 2552 1733
350 1 0.090 2.29 0.060 1.52 1.080 27.43 1.353 34.37 1.465 37.21 1947 2897 2062
 
400 1 0.090 2.29 0.060 1.52 1.123 28.53 1.398 35.51 1.527 38.79 2164 3220 2299
500 1/0 0.090 2.29 0.060 1.52 1.237 31.42 1.514 38.46 1.625 41.28 2596 3863 2864
 
600 1/0 0.090 2.29 0.060 1.52 1.278 32.47 1.553 39.45 1.682 42.72 2960 4405 3332
750 2/0 0.090 2.29 0.060 1.52 1.408 35.75 1.683 42.75 1.812 46.02 3648 5429 4189
1000 2/0 0.090 2.29 0.060 1.52 1.561 39.64 1.911 48.53 2.045 51.94 4674 6955 5359

*Steel armour is not permitted in single conductor cables.

Conductor Size Ampacity
30°C
Ambient A
Fittings
Power AWG
or kcmil
Bonding
AWG
Appleton T & B Commander Crouse-
Hinds
6 8 100 TMC8875 10465AL/ST050-465 TCA-50-089 ST050-465
4 6 135 TMC8875 10465AL/ST050-465 TCA-50-089 ST050-465
 
3 6 155 TMC8875 10465AL/ST050-465 TCA-50-089 ST050-465
2 6 180 TMC8875 10466AL/ST050-466 TCA-50-098 ST050-466
1 4 210 TMC118100 10467AL/ST075-467 TCA-75-106 ST075-467
 
1/0 4 245 TMC118100 10467AL/ST075-467 TCA-75-106 ST075-467
2/0 4 285 TMC118100 10468AL/ST075-468 TCA-75-118 ST075-468
3/0 3 330 TMC118100 10468AL/ST075-468 TCA--100-135 ST075-468
4/0 3 385 TMC140125 10469AL/ST100-469 TCA-100-135 ST100-469
 
250 2 425 TMC140125 10469AL/ST100-469 TCA-125-151 ST100-469
300 2 480 TMC140125 10470AL/ST125-470 TCA-125-151 ST125-470
350 1 530 TMC140125 10470AL/ST125-470 TCA-125-151 ST125-470
 
400 1 575 TMC140125 10470AL/ST125-470 TCA-125-167 ST125-470
500 1/0 660 TMC140125 10550AL/ST125-550 TCA-125-167 ST125-550
 
600 1/0 740 TMC140125 10471AL/ST125-471 TCA-125-182 ST125-471
750 2/0 845 TMC206200 10472AL/ST150-472 TCA-150-192 ST150-472
1000 2/0 1000 TMC206200 10472AL/ST150-473 TCA-150-208 ST150-473

††Ensure that only non-magnetic connectors, locknuts and ground bushings are used.

To Top